Conventional Fire Alarm Panel LX-EFC802-1

LX-EFC802-1 is a 1-zone conventional fire alarm control panel from the LX-EFC802 series. It supports up to 20 conventional heat or smoke detectors per zone with no limit on manual call points, and provides two sounder circuits for alarm devices. The panel runs on 220-230VAC 50/60Hz with a 24VDC typical output, automatic mains/standby switchover and a built-in charger for two 12V lead-acid batteries. Fault supervision covers mains, charger and batteries, while front-panel LEDs and functional buttons simplify operation. The 27.3 x 20 x 7.7 cm cabinet is finished in black or white, and the series scales from 1 to 32 zones.

Key Product Specifications

• Analogue conventional detector inputs: 20 heat/smoke detectors
• No limit of manual call points per zone
• Automatic power switchover: mains power and stand-by power
• Standby battery backup with built-in charging
• External pushbuttons keyswitch activated
• Internal power supply 24VDC
• Auxiliary output 24VDC
• External LED indicators
• Fault supervision and notification: mains, charger and batteries
• Succinct functional buttons: friendly user interface for easy operation and recognition
• Automatic loading and testing of battery
• Line fault monitored for open circuit/short circuit
• End of line resistor supplied for sounder circuit
• Evacuation: alarm resound
• Color: Black or White

Technical Data

ModelNumber of ZonesSounder CircuitsAC InputDC OutputBatteryOperation TemperatureHumidityCabinet Size
LX-EFC802-112 Circuits220V-230VAC 50/60Hz24VDC typicalLead-acid 1.2AH/12V*2pcs-10℃ to +40℃5 to 95% RH, non-condensing27.3*20*7.7CM
LX-EFC802-222 Circuits220V-230VAC 50/60Hz24VDC typicalLead-acid 1.2AH/12V*2pcs-10℃ to +40℃5 to 95% RH, non-condensing31*25*10CM
LX-EFC802-332 Circuits220V-230VAC 50/60Hz24VDC typicalLead-acid 1.2AH/12V*2pcs-10℃ to +40℃5 to 95% RH, non-condensing31*25*10CM
LX-EFC802-442 Circuits220V-230VAC 50/60Hz24VDC typicalLead-acid 1.2AH/12V*2pcs-10℃ to +40℃5 to 95% RH, non-condensing31*25*10CM
LX-EFC802-552 Circuits220V-230VAC 50/60Hz24VDC typicalLead-acid 2.5AH/12V*2pcs-10℃ to +40℃5 to 95% RH, non-condensing410*318*105CM
LX-EFC802-662 Circuits220V-230VAC 50/60Hz24VDC typicalLead-acid 2.5AH/12V*2pcs-10℃ to +40℃5 to 95% RH, non-condensing410*318*105CM
LX-EFC802-772 Circuits220V-230VAC 50/60Hz24VDC typicalLead-acid 2.5AH/12V*2pcs-10℃ to +40℃5 to 95% RH, non-condensing410*318*105CM
LX-EFC802-882 Circuits220V-230VAC 50/60Hz24VDC typicalLead-acid 2.5AH/12V*2pcs-10℃ to +40℃5 to 95% RH, non-condensing410*318*105CM
LX-EFC802-992 Circuits220V-230VAC 50/60Hz24VDC typicalLead-acid 2.5AH/12V*2pcs-10℃ to +40℃5 to 95% RH, non-condensing410*318*105CM
LX-EFC802-10102 Circuits220V-230VAC 50/60Hz24VDC typicalLead-acid 2.5AH/12V*2pcs-10℃ to +40℃5 to 95% RH, non-condensing410*318*105CM
LX-EFC802-11112 Circuits220V-230VAC 50/60Hz24VDC typicalLead-acid 2.5AH/12V*2pcs-10℃ to +40℃5 to 95% RH, non-condensing410*318*105CM
LX-EFC802-12122 Circuits220V-230VAC 50/60Hz24VDC typicalLead-acid 2.5AH/12V*2pcs-10℃ to +40℃5 to 95% RH, non-condensing410*318*105CM
LX-EFC802-13132 Circuits220V-230VAC 50/60Hz24VDC typicalLead-acid 2.5AH/12V*2pcs-10℃ to +40℃5 to 95% RH, non-condensing513*318*105CM
LX-EFC802-14142 Circuits220V-230VAC 50/60Hz24VDC typicalLead-acid 2.5AH/12V*2pcs-10℃ to +40℃5 to 95% RH, non-condensing513*318*105CM
LX-EFC802-15152 Circuits220V-230VAC 50/60Hz24VDC typicalLead-acid 2.5AH/12V*2pcs-10℃ to +40℃5 to 95% RH, non-condensing513*318*105CM
LX-EFC802-16162 Circuits220V-230VAC 50/60Hz24VDC typicalLead-acid 2.5AH/12V*2pcs-10℃ to +40℃5 to 95% RH, non-condensing513*318*105CM
LX-EFC802-17172 Circuits220V-230VAC 50/60Hz24VDC typicalLead-acid 2.5AH/12V*2pcs-10℃ to +40℃5 to 95% RH, non-condensing513*318*105CM
LX-EFC802-18182 Circuits220V-230VAC 50/60Hz24VDC typicalLead-acid 2.5AH/12V*2pcs-10℃ to +40℃5 to 95% RH, non-condensing513*318*105CM
LX-EFC802-19192 Circuits220V-230VAC 50/60Hz24VDC typicalLead-acid 2.5AH/12V*2pcs-10℃ to +40℃5 to 95% RH, non-condensing615*384*105CM
LX-EFC802-20202 Circuits220V-230VAC 50/60Hz24VDC typicalLead-acid 2.5AH/12V*2pcs-10℃ to +40℃5 to 95% RH, non-condensing615*384*105CM
LX-EFC802-21212 Circuits220V-230VAC 50/60Hz24VDC typicalLead-acid 2.5AH/12V*2pcs-10℃ to +40℃5 to 95% RH, non-condensing615*384*105CM
LX-EFC802-22222 Circuits220V-230VAC 50/60Hz24VDC typicalLead-acid 2.5AH/12V*2pcs-10℃ to +40℃5 to 95% RH, non-condensing615*384*105CM
LX-EFC802-23232 Circuits220V-230VAC 50/60Hz24VDC typicalLead-acid 2.5AH/12V*2pcs-10℃ to +40℃5 to 95% RH, non-condensing615*384*105CM
LX-EFC802-24242 Circuits220V-230VAC 50/60Hz24VDC typicalLead-acid 2.5AH/12V*2pcs-10℃ to +40℃5 to 95% RH, non-condensing615*384*105CM
LX-EFC802-25252 Circuits220V-230VAC 50/60Hz24VDC typicalLead-acid 2.5AH/12V*2pcs-10℃ to +40℃5 to 95% RH, non-condensing615*384*105CM
LX-EFC802-26262 Circuits220V-230VAC 50/60Hz24VDC typicalLead-acid 2.5AH/12V*2pcs-10℃ to +40℃5 to 95% RH, non-condensing615*384*105CM
LX-EFC802-27272 Circuits220V-230VAC 50/60Hz24VDC typicalLead-acid 2.5AH/12V*2pcs-10℃ to +40℃5 to 95% RH, non-condensing615*384*105CM
LX-EFC802-28282 Circuits220V-230VAC 50/60Hz24VDC typicalLead-acid 2.5AH/12V*2pcs-10℃ to +40℃5 to 95% RH, non-condensing615*384*105CM
LX-EFC802-29292 Circuits220V-230VAC 50/60Hz24VDC typicalLead-acid 2.5AH/12V*2pcs-10℃ to +40℃5 to 95% RH, non-condensing615*384*105CM
LX-EFC802-30302 Circuits220V-230VAC 50/60Hz24VDC typicalLead-acid 2.5AH/12V*2pcs-10℃ to +40℃5 to 95% RH, non-condensing615*384*105CM
LX-EFC802-31312 Circuits220V-230VAC 50/60Hz24VDC typicalLead-acid 2.5AH/12V*2pcs-10℃ to +40℃5 to 95% RH, non-condensing615*384*105CM
LX-EFC802-32322 Circuits220V-230VAC 50/60Hz24VDC typicalLead-acid 2.5AH/12V*2pcs-10℃ to +40℃5 to 95% RH, non-condensing615*384*105CM

Why Choose Lixin LX-EFC802-1 Conventional Fire Alarm Panel?

1-32 Zone Platform

The LX-EFC802 series covers installations from 1 to 32 zones with the same interface, so a panel can be selected for the exact size of the building.

20 Detectors per Zone

Each zone accepts up to 20 conventional heat or smoke detectors, with no limit on the number of manual call points.

Mains/Standby Switchover + Charger

Automatic changeover to standby batteries and a built-in charger keep the panel running during a mains failure.

Application Scenarios

LX-EFC802-1 Conventional Fire Alarm Panel Is Widely Used In

Get Your Customized Solution