LX-CFC803-16 is a 16-zone conventional fire alarm control panel from the LX-CFC803 series, using the same compact flame-retardant ABS housing as the 1-zone model. Each of the 16 zones accepts up to 40 conventional heat or smoke detectors with no limit on manual call points, and four sounder circuits drive alarm devices. A 3.2-inch colour touch screen with LEDs and buttons provides clear status and easy operation, while the 220-240VAC 50/60Hz supply gives a 29VDC typical output with professional battery charge/discharge protection. Global fire and fault relays, independent zone relays, zone disable/test functions and selectable sounder output modes are included.
Key Product Specifications
• Analogue conventional detector inputs: 40 heat/smoke detectors
• No limit of manual call points per zone
• Full flame retardant ABS housing, high integration
• The same housing size achieves 1-16 zones
• Good human-computer interaction: 3.2-inch colorful touch screen, LED indication and buttons
• Professional battery charging and discharging protection to extend battery life
• Global fire alarm relay and fault relay
• Independent zone relay output (can be set to fire or fault as required)
• Zone disable and test functions
• Sounder output working mode setting: No output / Delay output / Immediate output
Technical Data
| Model | Number of Zones | Sounder Circuits | AC Input | DC Output | Battery | Operation Temperature | Humidity | Cabinet Size |
|---|---|---|---|---|---|---|---|---|
| LX-CFC803-1 | 1 | 2 Circuits | 220V-240VAC 50/60Hz | 29VDC typical | Lead-acid 1.2AH/12V*2pcs | 0℃ to +40℃ | 5 to 95% RH, non-condensing | 28*25*9.3CM |
| LX-CFC803-2 | 2 | 2 Circuits | 220V-240VAC 50/60Hz | 29VDC typical | Lead-acid 1.2AH/12V*2pcs | 0℃ to +40℃ | 5 to 95% RH, non-condensing | 28*25*9.3CM |
| LX-CFC803-3 | 3 | 2 Circuits | 220V-240VAC 50/60Hz | 29VDC typical | Lead-acid 1.2AH/12V*2pcs | 0℃ to +40℃ | 5 to 95% RH, non-condensing | 28*25*9.3CM |
| LX-CFC803-4 | 4 | 2 Circuits | 220V-240VAC 50/60Hz | 29VDC typical | Lead-acid 1.2AH/12V*2pcs | 0℃ to +40℃ | 5 to 95% RH, non-condensing | 28*25*9.3CM |
| LX-CFC803-5 | 5 | 4 Circuits | 220V-240VAC 50/60Hz | 29VDC typical | Lead-acid 2.5AH/12V*2pcs | 0℃ to +40℃ | 5 to 95% RH, non-condensing | 28*25*9.3CM |
| LX-CFC803-6 | 6 | 4 Circuits | 220V-240VAC 50/60Hz | 29VDC typical | Lead-acid 2.5AH/12V*2pcs | 0℃ to +40℃ | 5 to 95% RH, non-condensing | 28*25*9.3CM |
| LX-CFC803-7 | 7 | 4 Circuits | 220V-240VAC 50/60Hz | 29VDC typical | Lead-acid 2.5AH/12V*2pcs | 0℃ to +40℃ | 5 to 95% RH, non-condensing | 28*25*9.3CM |
| LX-CFC803-8 | 8 | 4 Circuits | 220V-240VAC 50/60Hz | 29VDC typical | Lead-acid 2.5AH/12V*2pcs | 0℃ to +40℃ | 5 to 95% RH, non-condensing | 28*25*9.3CM |
| LX-CFC803-9 | 9 | 4 Circuits | 220V-240VAC 50/60Hz | 29VDC typical | Lead-acid 2.5AH/12V*2pcs | 0℃ to +40℃ | 5 to 95% RH, non-condensing | 28*25*9.3CM |
| LX-CFC803-10 | 10 | 4 Circuits | 220V-240VAC 50/60Hz | 29VDC typical | Lead-acid 2.5AH/12V*2pcs | 0℃ to +40℃ | 5 to 95% RH, non-condensing | 28*25*9.3CM |
| LX-CFC803-11 | 11 | 4 Circuits | 220V-240VAC 50/60Hz | 29VDC typical | Lead-acid 2.5AH/12V*2pcs | 0℃ to +40℃ | 5 to 95% RH, non-condensing | 28*25*9.3CM |
| LX-CFC803-12 | 12 | 4 Circuits | 220V-240VAC 50/60Hz | 29VDC typical | Lead-acid 2.5AH/12V*2pcs | 0℃ to +40℃ | 5 to 95% RH, non-condensing | 28*25*9.3CM |
| LX-CFC803-13 | 13 | 4 Circuits | 220V-240VAC 50/60Hz | 29VDC typical | Lead-acid 2.5AH/12V*2pcs | 0℃ to +40℃ | 5 to 95% RH, non-condensing | 28*25*9.3CM |
| LX-CFC803-14 | 14 | 4 Circuits | 220V-240VAC 50/60Hz | 29VDC typical | Lead-acid 2.5AH/12V*2pcs | 0℃ to +40℃ | 5 to 95% RH, non-condensing | 28*25*9.3CM |
| LX-CFC803-15 | 15 | 4 Circuits | 220V-240VAC 50/60Hz | 29VDC typical | Lead-acid 2.5AH/12V*2pcs | 0℃ to +40℃ | 5 to 95% RH, non-condensing | 28*25*9.3CM |
| LX-CFC803-16 | 16 | 4 Circuits | 220V-240VAC 50/60Hz | 29VDC typical | Lead-acid 2.5AH/12V*2pcs | 0℃ to +40℃ | 5 to 95% RH, non-condensing | 28*25*9.3CM |
Why Choose Lixin LX-CFC803-16 Conventional Fire Alarm Panel?
16 Zones, 4 Sounder Circuits
Sixteen supervised zones and four sounder circuits cover medium-sized buildings from one compact panel.
3.2-inch Colour Touch Screen
The colour touch screen, LEDs and buttons make alarm checking, zone disable and testing simple.
Independent Zone Relays
Each zone has its own relay output, configurable for fire or fault signalling to other systems.
- Quality: 100% Inspection
- Packaging: Export Standard Carton
- Service: Timely Full Support
Application Scenarios
LX-CFC803-16 Conventional Fire Alarm Panel Is Widely Used In
- Office Buildings – Office towers, business hubs and large-scale commercial complexes of all sizes
- Retail Stores – Shopping centers, retail stores and all customer-facing commercial premises
- Hospitality Venues – Hotels, restaurants and diversified commercial service and catering environments
- Residential Buildings – Apartments, condominiums and various multi-family residential housing units
- Hospital——Inpatient towers, outpatient clinics and various auxiliary medical support units
- Factory——Manufacturing plants, assembly workshops and various multi-purpose factory production units