Conventional Fire Alarm Panel LX-801-28

LX-801-28 is a 28-zone conventional fire alarm control panel from the LX-801 series, housed in a 31 x 56 x 9.6 cm ivory cabinet. Each zone supports up to 20 conventional heat or smoke detectors with no limit on manual call points, and two sounder circuits provide 24V nominal output with a 10K end-of-line resistor. The 240VAC ±10% 50/60Hz supply features automatic mains/standby switchover and a built-in charger for two 12V lead-acid batteries, with glass-fuse protection on the mains, sounder and charging circuits. Zoned red alarm and yellow trouble indicators and automatic battery testing simplify commissioning and maintenance.

Key Product Specifications

• Analogue conventional detector inputs: 20 heat/smoke detectors
• No limit of manual call points per zone
• Charging voltage protection: 1.6Ah glass fuse
• Sounder output: 24V nominal, EOL 10K resistor
• Auxiliary contacts: 30VDC, 1A max. NC/NO
• Main supply protection: glass fuse
• Sounder protection: 2*500mA glass fuse
• Battery reversal protection via charger glass fuse
• Zone EOL: 5.6K resistor
• Zoned visual red alarm and yellow trouble indicators
• Continuous signal during alarm
• Standby battery backup with built-in charging
• Automatic power switchover: mains power and stand-by power
• Automatic testing: low / no power, battery status and loading test
• Evacuation: alarm resound
• Color: Ivory

Technical Data

ModelNumber of ZonesSounder CircuitsAC InputDC OutputBatteryOperation TemperatureHumidityCabinet Size
LX-801-112 Circuits240VAC±10% 50/60Hz24VDC typicalLead-acid 1.2AH/12V*2pcs0℃ to +40℃≤95% RH, non-condensing30*20*9.6CM
LX-801-222 Circuits240VAC±10% 50/60Hz24VDC typicalLead-acid 1.2AH/12V*2pcs0℃ to +40℃≤95% RH, non-condensing30*20*9.6CM
LX-801-332 Circuits240VAC±10% 50/60Hz24VDC typicalLead-acid 1.2AH/12V*2pcs0℃ to +40℃≤95% RH, non-condensing30*20*9.6CM
LX-801-442 Circuits240VAC±10% 50/60Hz24VDC typicalLead-acid 1.2AH/12V*2pcs0℃ to +40℃≤95% RH, non-condensing30*20*9.6CM
LX-801-552 Circuits240VAC±10% 50/60Hz24VDC typicalLead-acid 2.5AH/12V*2pcs0℃ to +40℃≤95% RH, non-condensing31*32*9.6CM
LX-801-662 Circuits240VAC±10% 50/60Hz24VDC typicalLead-acid 2.5AH/12V*2pcs0℃ to +40℃≤95% RH, non-condensing31*32*9.6CM
LX-801-772 Circuits240VAC±10% 50/60Hz24VDC typicalLead-acid 2.5AH/12V*2pcs0℃ to +40℃≤95% RH, non-condensing31*32*9.6CM
LX-801-882 Circuits240VAC±10% 50/60Hz24VDC typicalLead-acid 2.5AH/12V*2pcs0℃ to +40℃≤95% RH, non-condensing31*32*9.6CM
LX-801-992 Circuits240VAC±10% 50/60Hz24VDC typicalLead-acid 2.5AH/12V*2pcs0℃ to +40℃≤95% RH, non-condensing31*32*9.6CM
LX-801-10102 Circuits240VAC±10% 50/60Hz24VDC typicalLead-acid 2.5AH/12V*2pcs0℃ to +40℃≤95% RH, non-condensing31*32*9.6CM
LX-801-11112 Circuits240VAC±10% 50/60Hz24VDC typicalLead-acid 2.5AH/12V*2pcs0℃ to +40℃≤95% RH, non-condensing31*32*9.6CM
LX-801-12122 Circuits240VAC±10% 50/60Hz24VDC typicalLead-acid 2.5AH/12V*2pcs0℃ to +40℃≤95% RH, non-condensing31*32*9.6CM
LX-801-13132 Circuits240VAC±10% 50/60Hz24VDC typicalLead-acid 2.5AH/12V*2pcs0℃ to +40℃≤95% RH, non-condensing31*44*9.6CM
LX-801-14142 Circuits240VAC±10% 50/60Hz24VDC typicalLead-acid 2.5AH/12V*2pcs0℃ to +40℃≤95% RH, non-condensing31*44*9.6CM
LX-801-15152 Circuits240VAC±10% 50/60Hz24VDC typicalLead-acid 2.5AH/12V*2pcs0℃ to +40℃≤95% RH, non-condensing31*44*9.6CM
LX-801-16162 Circuits240VAC±10% 50/60Hz24VDC typicalLead-acid 2.5AH/12V*2pcs0℃ to +40℃≤95% RH, non-condensing31*44*9.6CM
LX-801-17172 Circuits240VAC±10% 50/60Hz24VDC typicalLead-acid 2.5AH/12V*2pcs0℃ to +40℃≤95% RH, non-condensing31*44*9.6CM
LX-801-18182 Circuits240VAC±10% 50/60Hz24VDC typicalLead-acid 2.5AH/12V*2pcs0℃ to +40℃≤95% RH, non-condensing31*44*9.6CM
LX-801-19192 Circuits240VAC±10% 50/60Hz24VDC typicalLead-acid 2.5AH/12V*2pcs0℃ to +40℃≤95% RH, non-condensing31*44*9.6CM
LX-801-20202 Circuits240VAC±10% 50/60Hz24VDC typicalLead-acid 2.5AH/12V*2pcs0℃ to +40℃≤95% RH, non-condensing31*44*9.6CM
LX-801-21212 Circuits240VAC±10% 50/60Hz24VDC typicalLead-acid 2.5AH/12V*2pcs0℃ to +40℃≤95% RH, non-condensing31*56*9.6CM
LX-801-22222 Circuits240VAC±10% 50/60Hz24VDC typicalLead-acid 2.5AH/12V*2pcs0℃ to +40℃≤95% RH, non-condensing31*56*9.6CM
LX-801-23232 Circuits240VAC±10% 50/60Hz24VDC typicalLead-acid 2.5AH/12V*2pcs0℃ to +40℃≤95% RH, non-condensing31*56*9.6CM
LX-801-24242 Circuits240VAC±10% 50/60Hz24VDC typicalLead-acid 2.5AH/12V*2pcs0℃ to +40℃≤95% RH, non-condensing31*56*9.6CM
LX-801-25252 Circuits240VAC±10% 50/60Hz24VDC typicalLead-acid 2.5AH/12V*2pcs0℃ to +40℃≤95% RH, non-condensing31*56*9.6CM
LX-801-26262 Circuits240VAC±10% 50/60Hz24VDC typicalLead-acid 2.5AH/12V*2pcs0℃ to +40℃≤95% RH, non-condensing31*56*9.6CM
LX-801-27272 Circuits240VAC±10% 50/60Hz24VDC typicalLead-acid 2.5AH/12V*2pcs0℃ to +40℃≤95% RH, non-condensing31*56*9.6CM
LX-801-28282 Circuits240VAC±10% 50/60Hz24VDC typicalLead-acid 2.5AH/12V*2pcs0℃ to +40℃≤95% RH, non-condensing31*56*9.6CM
LX-801-29292 Circuits240VAC±10% 50/60Hz24VDC typicalLead-acid 2.5AH/12V*2pcs0℃ to +40℃≤95% RH, non-condensing31*68*9.6CM
LX-801-30302 Circuits240VAC±10% 50/60Hz24VDC typicalLead-acid 2.5AH/12V*2pcs0℃ to +40℃≤95% RH, non-condensing31*68*9.6CM
LX-801-31312 Circuits240VAC±10% 50/60Hz24VDC typicalLead-acid 2.5AH/12V*2pcs0℃ to +40℃≤95% RH, non-condensing31*68*9.6CM
LX-801-32322 Circuits240VAC±10% 50/60Hz24VDC typicalLead-acid 2.5AH/12V*2pcs0℃ to +40℃≤95% RH, non-condensing31*68*9.6CM
LX-801-33332 Circuits240VAC±10% 50/60Hz24VDC typicalLead-acid 2.5AH/12V*2pcs0℃ to +40℃≤95% RH, non-condensing31*68*9.6CM
LX-801-34342 Circuits240VAC±10% 50/60Hz24VDC typicalLead-acid 2.5AH/12V*2pcs0℃ to +40℃≤95% RH, non-condensing31*68*9.6CM
LX-801-35352 Circuits240VAC±10% 50/60Hz24VDC typicalLead-acid 2.5AH/12V*2pcs0℃ to +40℃≤95% RH, non-condensing31*68*9.6CM
LX-801-36362 Circuits240VAC±10% 50/60Hz24VDC typicalLead-acid 2.5AH/12V*2pcs0℃ to +40℃≤95% RH, non-condensing31*68*9.6CM

Why Choose Lixin LX-801-28 Conventional Fire Alarm Panel?

28 Zones, 31 x 56 cm Cabinet

A wide ivory cabinet gives clear separation between 28 zone indicators and the main control section.

20 Detectors per Zone

Each zone supports up to 20 conventional detectors, with no limit on manual call points.

Automatic Battery Testing

Low/no power, battery status and loading tests run automatically, reducing routine maintenance work.